D&R AXITE/AXUM (MambaNet)

D&R AXITE and AXUM consoles use the MambaNet protocol for communication between their components. mAirList joins the MambaNet network as a node, and executes remote control commands when its actuators are switched by the console. The required mbn.dll library is included with mAirList.

Configuration

In the configuration app or Control Panel, go to Remote Control and add an interface of type D&R AXITE/AXUM (MambaNet) (D&R category).

General

  • Communication: Select how mAirList connects to the MambaNet network:
    • TCP or UDP: Enter the IP and Port (default 34848) of the console.
    • Ethernet: Communicate directly on the Ethernet layer, through the selected network Device.
  • Address and Unique ID: The MambaNet address and unique ID of the mAirList node. Each node in the network must have a unique ID; only change these values if there is more than one mAirList node.

Commands

On the Commands tab, enter the commands to execute when an actuator of the mAirList node is switched On and Off. The actuators can be assigned to console functions (e.g. buttons or fader start) in the console configuration.