This is the multi-page printable view of this section. Click here to print.

Return to the regular view of this page.

Wheatstone

This section covers the integration with Wheatstone WheatNet-IP systems:

1 - WheatNet-IP Mixer

This interface connects mAirList to a WheatNet-IP mixing console (e.g. an LXE, Strata or GSX surface) via TCP/IP, and executes remote control commands when an input channel is switched on or off, or when its CUE is switched on or off.

Configuration

In the configuration app or Control Panel, go to Remote Control and add an interface of type WheatNet-IP Mixer (Wheatstone category).

On the Connection tab, enter the Host name or IP of the mixer engine, and the Port (default 55777).

On the Input Commands tab, enter the commands for each input (1 to 64) and function:

  • Channel On / Channel Off
  • CUE On / CUE Off

mAirList only subscribes to the events of those inputs and functions for which a command is configured.

2 - WheatNet-IP BLADE

This interface connects mAirList to a WheatNet-IP BLADE via TCP/IP, and uses the software logic I/Os (SLIOs) of the BLADE to exchange logic signals with the WheatNet-IP network.

Configuration

In the configuration app or Control Panel, go to Remote Control and add an interface of type WheatNet-IP BLADE (Wheatstone category).

On the Connection tab, enter the Host name or IP of the BLADE, and the Port (default 55776).

On the SLIO tab, enter the remote control commands to execute when an SLIO (1 to 192) goes ON and OFF.

Scripting

SLIOs can also be read and set from background scripts through WheatNetBladeRemote(<index>), using the methods SetSLIO(Index, State), GetSLIOState(Index), QuerySLIO(Index) and SubscribeSLIO(Index).