Ember+ Consumer

    The Ember+ Consumer remote connects to an Ember+ provider (e.g. a mixing console) via TCP/IP, and executes remote control commands when the value of a parameter changes.

    Configuration

    In the configuration app or Control Panel, go to Remote Control and add an interface of type Ember+ Consumer (Ember+ category).

    Connection

    • Host name or IP and Port: The address of the Ember+ provider. The default port is 9000.
    • Keepalive Interval: If set, mAirList sends keepalive requests in this interval, so that a broken connection is detected and re-established.

    The Monitor helps you to find the parameters you are interested in. Check Enable Monitor, then operate the device: Each parameter change is displayed in the list. Double-click a parameter to add it to the command list.

    Parameter Tree

    The Parameter Tree tab displays the complete parameter tree of the provider, along with the current values. Double-click a parameter to add it to the command list.

    Commands

    The Commands tab contains the list of parameter changes that mAirList reacts to. Each entry consists of:

    • Parameter: The path of the parameter in the Ember+ tree.
    • Value Condition and Value: A condition for the new value of the parameter: =, !=, <, <=, >=, > compare it to the specified Value, * matches any value.