This section covers the integration with mixing consoles by Barth.
1 - D.MAX
The D.MAX remote connects mAirList to a Barth D.MAX mixing console via a serial port. mAirList receives the state of the fader start (GO), PFL, NEXT and OPT keys, as well as the fader levels, and executes the configured remote control commands.
Configuration
In the configuration app or Control Panel, go to Remote Control and add an interface of type D.MAX (Barth category).
Select the COM Port that the console is connected to. The port parameters (baud rate etc.) must be set up in the Serial Ports section of the configuration first.
Commands
The commands are assigned to the console inputs (1 to 32), not to the fader numbers. mAirList keeps track of which input is currently routed to which fader, so the commands follow the source when it is assigned to a different fader.
There is a separate tab for each key type: Fader (fader start), PFL, Next, and OPT. For each input, enter the command to execute when the key goes ON and OFF.
A fader start only triggers the Fader command when the GO key is active and the fader is open; closing the fader or releasing the GO key triggers the OFF command.
Volume
On the Volume tab, you can enter a command for each input that is executed whenever its fader level changes. The following variables can be used:
$VALUE– the raw fader value as sent by the console,$DB– the fader level in dB.
Example: PLAYER 1-1 VOLUME $DB